Professional benchtop pH meter, 7 inch TFT display, stores up to 1000 data sets, setup menu contains 17 options, accuracy: 0.002 pH.
pH Mode:
• Professional benchtop pH meter is equipped with a 7 inch TFT display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic temperature compensation ensures accurate readings over the entire range.
• Solution temperature coefficient compensates for the pure water samples and references
the pH to 25°C.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Other Features:
• Auto-Read function senses and locks the measurement endpoint.
• Timed Interval Readings sends the measurement data to a PC or printer.
• Limit Alarm automatically alerts when reading exceeds the specified range.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Calibration log shows the date, time, calibration points, offset and pH slope.
• Password protection prevents the unauthorized calibration and settings.
• Expanded memory stores or recalls up to 1000 data sets.
• Reset function automatically resumes all settings back to the factory defaults.
Specifications
| Model | A120 |
| pH | |
| Range | -2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 pH, selectable |
| Accuracy | ±0.002 pH |
| Calibration Points | 1 to 5 points |
| pH Buffer Options | USA / NIST / DIN / 5 custom buffers |
| ORP | |
| Range | -2000.0 to 2000.0 mV |
| Resolution | 0.1 mV |
| Accuracy | ±0.2 mV |
| Calibration Points | 1 point |
| Measurement Modes | Relative / Absolute mV |
| Temperature | |
| Range | 0 to 105°C / 32 to 221°F |
| Resolution | 0.1°C/°F |
| Accuracy | ±0.5°C / ±0.9°F |
| Offset Calibration | 1 point |
| Calibration Range | Reading ±10°C/°F |
| Other Specifications | |
| Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic |
| Stability Criteria | Standard / High-accuracy |
| Measurement Modes | Continuous / Auto-read measurement endpoint |
| Timed Interval Readings | 10 / 30 / 60 seconds, 10 / 30 minutes or off |
| Calibration Due Alarm | 1 to 31 days or off |
| High/Low Limit Alarm | Selectable |
| Password Protection | 4 digits |
| Memory | Stores up to 1000 data sets |
| Output | USB communication interface |
| Connector | BNC, 3.5 mm jack socket |
| Display | 7 inch TFT LCD |
| Power Supply | 12V DC power adapter |
| Dimensions | 240 × 220 × 80 mm |
| Weight | 1.7 kg |